Percutaneous Osteosynthesis of Thoraco Lumbar Fractures: Is Post CT-Scann Mandatory?
Asian Journal of Orthopaedic Research, Volume 6, Issue 2,
Page 78-84
Abstract
Introduction: Percutaneous fixation of traumatic thoraco-lumbar spine fractures represents an innovative technique.
The objective of our work was to evaluate the pedicle screw placement of this technique using a post-operative CT-scan.
Methods: We conducted a retrospective and descriptive study including 30 cases over a period of 2.5 years. We evaluated postoperative CT-scan parameters by studying the accuracy of pedicle screw placement using the Rao classification.
Results: The mean age was 44 years, the sex ratio was 1.3 with 17 male and 13 female. The lesion was located at the thoraco-lumbar hinge in 73.34% and in 70% it was classified as A3 with a mean posterior wall recession of 36.33%. A total of 186 pedicle screws were inserted. According to the classification of Rao 38.7% of the screws were misplaced, of which 11.29% were non-minor perforations (grade 2 and 3).
Conclusion: Postoperative CT to check the precise placement of the pedicle screws in asymptomatic patients has not shown any benefit: 11.29 % were major misplaced without any clinical repercussion. Therefore, a postoperative CT scan must be critically discussed and should be reserved for symptomatic patients.
- Spine
- fracture fixation
- CT scan
- pedicle screw
How to Cite
References
Chapman T, Blizzard D, Brown C. Erratum to: CT accuracy of percutaneous versus open pedicle screw techniques: a series of 1609 screws. European Spine Journal. 2015;25.
DOI:10.1007/s00586-015-4163-z
Charles YP, Ntilikina Y, Collinet A, Schuller S, Garnon J, Godet J, et al. Accuracy and technical limits of percutaneous pedicle screw placement in the thoracolumbar spine. Surg Radiol Anat. 2021;43(6):843–853.
Aigner R, Bichlmaier C, Oberkircher L, Knauf T, König A, Lechler P, et al. Pedicle screw accuracy in thoracolumbar fractures- is routine postoperative CT scan necessary? BMC Musculoskelet Disord. 2021;22(1):986.
Wiesner L, Kothe R, Rüther W. Anatomic evaluation of two different techniques for the percutaneous insertion of pedicle screws in the lumbar spine. Spine (Phila Pa 1976). 1999;24(15):1599–1603.
Lien SB, Liou NH, Wu SS. Analysis of anatomic morphometry of the pedicles and the safe zone for through-pedicle procedures in the thoracic and lumbar spine. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2007;16:1215–22.
Chapman TM, Blizzard DJ, Brown CR. CT accuracy of percutaneous versus open pedicle screw techniques: A series of 1609 screws. European Spine Journal. 2016; 25:1781-1786.
Patel RD, Graziano GP, Vanderhave KL, Patel AA, Gerling MC. Facet Violation With the Placement of Percutaneous Pedicle Screws: Spine. 2011;36(26):E1749–E1752.
Choi WW, Green BA, Levi AD. Computer-assisted fluoroscopic targeting system for pedicle screw insertion. Neurosurgery. 2000;47(4):872–878.
Baird EO, McAnany SJ, Overley S, Skovrlj B, Guzman JZ, Qureshi SA. Accuracy of Percutaneous Pedicle Screw Placement: Does Training Level Matter? Clinical Spine Surgery: A Spine Publication. 2017; 30(6):E748–E753.
Heintel TM, Berglehner A, Meffert R. Accuracy of percutaneous pedicle screws for thoracic and lumbar spine fractures: a prospective trial. Eur Spine J. 2013; 22(3):495–502.
Raley DA, Mobbs RJ. Retrospective computed tomography scan analysis of percutaneously inserted pedicle screws for posterior transpedicular stabilization of the thoracic and lumbar spine: accuracy and complication rates. Spine (Phila Pa 1976). 2012;37(12):1092–1100.
Tinelli M, Matschke S, Adams M, Grützner PA, Münzberg M, Suda AJ. Correct positioning of pedicle screws with a percutaneous minimal invasive system in spine trauma. Orthopaedics & Traumatology: Surgery & Research. 2014;100(4): 389–393.
-
Abstract View: 2 times